Product Overview
Here is a list of the hookup diagrams for various generators. There are 4 icons to the right, click on “Bookmarks” to find a list of generator hookup drawings.
If you do not find your generator, please contact cbdsales@atkinsonel.com for the proper hookup diagram.
Please include the generator make & model, inverter brand, & battery bank voltage.
Honda EXXXXXIS Series requires a GSCM-mini-i
Outback 48 Volt inverter systems require isolation relay (A0365)
Note: Standby generators will not work with the GSCM or GSCM-Mini. Standby generators have their own control circuitry for monitoring utility power.
The Generator Start Control Module-mini (GSCM-mini) is a non-programmable micro-processor based generator start controller that is designed to auto start and stop gas or propane generators.
It supports three types of 3 or 4 wire gas-generator control: momentary, maintained or key ignition. It automatically disconnects the starter when a minimum generator AC Hz output is measured. It has a fixed crank time and over and under frequency shut down. The GSCM-mini is powered by 12 volts DC from the generator battery and can monitor the battery voltage and start the generator to charge its own battery. The GSCM-mini uses the generator AC output to know when the generator has stated and is running.
The GSCM-mini is also available in a mini diesel version, inverter version or a programmable version.
Europe, Australia & Japan please see GSCM-mini-50Hz.
Dimensions: W: 3.2” x H: 1.2" x D: .875"